← All articles
2026-09-16•~2 min readspirometrytube884101890031breathing circuitsingle-useICUGE

GE spirometry tubes: 884101 (3 m) and 890031 (2 m, ICU)

Single-use GE spirometry tubes: 884101 (3 m) and 890031 (2 m, for the ICU) — how to choose the length, rules of use, common mistakes and replacement.

Single-use spirometry tubes 884101 (3 m) and 890031 (2 m, ICU) for GE

Measuring respiratory volume and flow is an important part of assessing pulmonary function and controlling ventilation. Single-use tubes are used to connect the spirometer or respiratory monitor to the patient's flow.

This guide looks at spirometry tubes 884101 (3 m) and 890031 (2 m, for the intensive care unit) from the Medicaparts catalogue.

1. Why a spirometry tube is needed

The tube carries the respiratory flow to the sensor/spirometer, making it possible to measure:

  • •tidal volume (Vt);
  • •flow and volume-related values;
  • •spirometry parameters for functional diagnostics.

Single-use design:

  • •eliminates cross-infection between patients;
  • •provides hygiene for the procedure;
  • •simplifies logistics — no sterilisation required.

2. The items in detail

2.1. 884101 — single-use spirometry tube, 3 m

PN: 884101

  • •Single-use spirometry tube, 3 m long.
  • •Area of use — anaesthesiology, functional diagnostics, breathing circuit.
  • •The greater length is convenient when the equipment is placed at a distance.

2.2. 890031 — single-use spirometry tube, 2 m, ICU

PN: 890031

  • •Single-use spirometry tube, 2 m long.
  • •Used in the intensive care unit (ventilator).
  • •Compact length — less air gap, convenient at the patient's bedside.

3. How to choose the tube length

  • •Distance from the measurement point to the spirometer/monitor.
  • •Layout of the breathing circuit and the position of the equipment.
  • •The task — a long tube (884101, 3 m) for a flexible layout, a short one (890031, 2 m) for compact placement at the ICU bed.
When choosing, follow the manual for your equipment and the department protocol.

4. Technical specifications (typical)

PNLengthApplicationType
8841013 mspirometrysingle-use
8900312 mintensive care unitsingle-use

5. Rules of use

  • •Use a new tube for every procedure/patient.
  • •Check the integrity and tightness of the connections.
  • •Do not kink the tube, to avoid distorting the flow.
  • •Dispose of it after a single use, in line with protocol.

6. Common mistakes

  • •Reusing a single-use tube. Risk of infection and of inaccuracy.
  • •The wrong length. An awkward layout and unnecessary air gap.
  • •Kinking the tube. Distorts the flow measurement.
  • •A loose connection. Air leak and measurement error.

7. Delivery and purchasing

Medicaparts supplies original single-use spirometry tubes to Russia and CIS countries:

  • •Lead time is confirmed when the order is placed.
  • •Rare items: lead time is confirmed when the order is placed.
  • •Help with selection by model and application.
  • •Provision of accompanying documentation.

8. How to order

  1. Write on Telegram @GEpartsV_bot or by email to [email protected].
  2. State the PN you need (884101 or 890031) and the equipment model.
  3. An engineer will confirm compatibility and issue a quotation.
  4. Contract/invoice, prepayment, delivery.

9. Contacts

Sources: Medicaparts catalogue (products_current.json, PN 884101 / 890031); GE Healthcare documentation; the experience of service engineers.

Frequently asked questions

What role does a single-use spirometry tube (884101 / 890031) play?
The tube connects the spirometer/respiratory monitor to the flow in the breathing circuit, making it possible to measure respiratory volume and flow. The single-use design eliminates cross-infection, and it is used in anaesthesiology and the ICU.
What is the difference between 884101 (3 m) and 890031 (2 m, ICU)?
The difference is in length and area of application: 884101 is a 3 m tube for spirometry (usually in anaesthesiology/functional diagnostics); 890031 is a 2 m tube for the ICU. The length is chosen according to the configuration and the distance to the equipment.
How do I choose the right tube length for my equipment?
Take into account the distance from the measurement site to the spirometer/monitor and the layout of the breathing circuit. 3 m (884101) gives more freedom, 2 m (890031) is more compact with a smaller air gap. Check against the equipment manual.
How often should the spirometry tube be changed?
A single-use tube is intended for a single use/one patient and is replaced for every new procedure or according to the department protocol. Do not reuse it, to avoid cross-infection.
Where can I buy original spirometry tubes with delivery to Russia?
Medicaparts supplies original single-use tubes 884101 and 890031 to Russia and CIS countries; lead time is confirmed when the order is placed. Get in touch on Telegram @GEpartsV_bot.

Need the part number?

Send us the equipment model or the part number and we will check it against the catalogue. You can also search the parts catalogue directly.