2026-07-22•~4 min readlithium batterypatient monitorGECARESCAPEDashB450B650

GE lithium batteries for patient monitors: 2044978-004, 2017857-002, 2062895-001, 2036984-001 — choosing by series

GE lithium batteries for CARESCAPE B20/B30/B40, DASH 3000/4000/5000, B450 and B650 monitors. Comparison of PNs, voltage and service life. Compatibility and replacement.

Lithium batteries are a critical component of the portability of GE patient monitors. When a patient is transported within the clinic (operating block → intensive care unit → diagnostic department), the monitor must run on battery for 2-6 hours without recharging. Battery failure means the patient cannot be moved with monitoring in place — critical in intensive care.

For the GE monitor line four different batteries are produced — one for each series. In this article we look at how they differ, the signs that replacement is due, and the rules for transport.

1. Why original GE batteries matter

The battery management system (BMS) of GE monitors has a threefold incompatibility with third-party batteries:

  1. Mechanical interface: the depth of the battery compartment, the position of the retainers and the connector type are GE's own design. A third-party battery will not fit the compartment or will not lock in place, even if its electrical parameters match.
  2. Electronic identification: over the SMBus protocol the GE monitor reads a GE serial number from the battery chip. An unrecognised battery is not accepted for charging, and on power-up the message "Battery Communication Error" is displayed.
  3. Medical certification: GE batteries have been tested to IEC 62133 (safety of lithium batteries for medical use) and UN38.3 (approval for air transport), which meets the requirements of medical equipment quality control in the clinic and the conditions of air and sea import.

2. Technical characteristics of the four PNs

Parameter2044978-0042017857-0022062895-0012036984-001
Voltage11.1 V11.1 V10.8 V11.1 V
Capacity4.9 Ah4.9 Ah3.8 Ah(Flex-3S3P)
Energy55 Wh55 Wh41 Wh~55 Wh
Compatible monitorCARESCAPE B20/B30/B40DASH 3000/4000/5000CARESCAPE B450CARESCAPE B650
Service life~500 cycles~500 cycles~500 cycles~500 cycles

3. Compatibility by monitor model

ModelBattery PN
CARESCAPE B202044978-004
CARESCAPE B302044978-004
CARESCAPE B402044978-004
DASH 30002017857-002
DASH 40002017857-002
DASH 50002017857-002
CARESCAPE B4502062895-001
CARESCAPE B6502036984-001

⚠️ The 2044978-004 and 2017857-002 have fully identical electrical parameters (11.1V / 4.9Ah / 55Wh) but different PNs — because of differences in the mechanical interface of the battery compartment and the design of the retainers (the CARESCAPE and DASH series belong to different product generations). They are not interchangeable.

4. When to replace the battery

4 characteristic signs of a fault:

  1. Runtime < 2 hours after a full charge. The original runtime of a new battery is 4–6 hours of autonomous operation. If the time has dropped to < 2 hours, replacement is due.
  2. Noticeable heating during charging. The normal surface temperature during charging is 30-40 °C. If it is > 45 °C, internal resistance has risen and the battery is on the verge of failure.
  3. Swelling or leakage. Any deformation of the housing or traces of electrolyte means immediate replacement and disposal as hazardous waste.
  4. A "Battery Low" alarm within < 30 minutes of a full charge. The charge controller estimates internal resistance — if the battery rapidly "sags" under load, the monitor warns the operator.

Scheduled replacement: under intensive use (the monitor is moved daily) forced replacement every 24 months is recommended, regardless of symptoms.

5. Common mistakes

Trying to fit a "similar" battery. The two PNs 2044978-004 and 2017857-002 have identical electrical characteristics but are mechanically different — fitting the wrong PN can damage the monitor's battery compartment.

Using non-certified third-party batteries. A 30–50% saving turns into risk: 1) "Battery Communication Error" alarms in the operating theatre; 2) failure during patient transport; 3) breach of the hospital's procurement rules (no certificate).

Ignoring the "Battery Low" alarm. The monitor will continue to run from the mains, but at any power interruption it will switch off within 5–10 minutes. A risk to the patient during transfer.

Charging at sub-zero temperatures. Lithium batteries must not be charged at temperatures < 0 °C — irreversible degradation. In winter, on delivery to Russia, let the battery stand for 4-6 hours at room temperature before fitting.

Disposing of it in general waste. Spent lithium batteries are hazardous waste (UN 3480). Hand them in at specialised disposal points.

6. Transport to Russia

Lithium batteries fall under IATA DGR Class 9 (dangerous goods). For supply to Russia, batches of batteries travel by sea or rail with lithium battery marking under UN3480. Each batch is supplied with:

  • •a UN38.3 certificate (issued by GE for each batch);
  • •an MSDS (Material Safety Data Sheet);
  • •packaging marked "Lithium battery" with the hazard class indicated.

Air delivery is possible for single units (up to 100 Wh each — our 55 Wh units qualify), but as cargo only, not in hand luggage.

7. Where to buy original batteries

Medicaparts supplies all four models of GE lithium battery for patient monitors directly to Russia and the CIS countries, with lead time confirmed when the order is placed. When ordering, be sure to state the monitor model and the last 4 digits of the serial number — the manager will check them against the rating plate and select the correct PN. Contact — Telegram @GEpartsV_bot.

Sources: GE Healthcare Service Manual CARESCAPE B450/B650/Dash 3000-5000, Battery Specifications; IATA DGR 65th Edition, Class 9 — Lithium Batteries; Medicaparts' own experience of supplies in 2024–2026.

Frequently asked questions

Which monitors are 2044978-004, 2017857-002, 2062895-001 and 2036984-001 suitable for?
2044978-004 (11.1 V / 4.9 Ah / 55 Wh) is for CARESCAPE B20/B30/B40. 2017857-002 (the same 11.1 V / 4.9 Ah characteristics) is for DASH 3000/4000/5000. 2062895-001 (10.8 V / 3.8 Ah) is for CARESCAPE B450. 2036984-001 (Flex-3S3P / 11.1 V) is for CARESCAPE B650. Each PN has its own battery compartment form factor; interchangeability is not possible.
Can a third-party battery be used instead of an original GE one?
Technically you can buy a third-party battery with the same electrical characteristics, but that carries three risks: 1) a mismatch in the mechanical dimensions of the battery compartment (depth and latch positions differ for each monitor); 2) BMS protocol incompatibility: GE monitors read the serial number of the battery chip, so an unrecognised third-party battery does not charge or triggers an alarm on power-up; 3) the absence of GE medical certification — in the event of an incident it will not pass the medical institution's internal quality control. We strongly recommend original GE batteries.
How often should a monitor battery be replaced?
Forced replacement every 2 years is recommended, or immediately in the case of: 1) a runtime < 2 hours after a full charge (originally 4–6 hours); 2) noticeable heating during charging (>45 °C); 3) swelling or electrolyte leakage; 4) a "Battery Low" alarm appearing within < 30 minutes of a full charge. The service life of GE batteries is about 500 full charge-discharge cycles.
Can lithium batteries be transported to Russia by air?
Yes, but with restrictions: 1) each battery < 100 Wh (our 55 Wh units qualify) travels as ordinary cargo; 2) each package is marked with the lithium battery symbol; 3) a UN38.3 test report is required (GE supplies it as standard); 4) prohibited in hand luggage, cargo only. Batch supplies travel by sea or rail with lithium battery marking.
Where can I buy 2044978-004, 2017857-002, 2062895-001, 2036984-001 with delivery to Russia?
Original GE batteries 2044978-004, 2017857-002, 2062895-001, 2036984-001 are supplied by Medicaparts to Russia and the CIS with lead time confirmed when the order is placed. When ordering, state the monitor model and the last 4 digits of the serial number. Contact — Telegram @GEpartsV_bot.