← All articles
2026-09-28•~9 min readincubatorGiraffe OmniBedneonatologyinfant warmerhumidifierspare parts

Spare Parts for GE Infant Incubators and Warmers: Giraffe, OmniBed, Panda, Lullaby — Heating, Humidifier, Ventilation and Corometrics Boards

Spare parts for GE Giraffe, OmniBed, Panda and Lullaby infant incubators and warmers: assembly M1110788-S, bed 6600-1041-700, humidifier 6600-0224-850.

Heating, humidification and environment control are the three systems that determine how much time an incubator or infant warmer stays in service. Failure of a bed heating module, a humidifier or an ambient sensor does not stop a department entirely, but it closes a specific place in the ward: the bed complement shrinks, and a replacement has to wait for delivery. That is why the Giraffe, OmniBed, Panda and Lullaby fleet is easier to service from a pre-assembled spare parts stock rather than on a failure-by-failure basis.

This guide covers twelve items that have entered the MediAccessori catalog for GE incubators and infant warmers: heating, humidification, ventilation and environment control assemblies, mechanical consumables, and Corometrics 250 labor monitoring boards. For each item the official catalog description, compatible equipment, an approximate price in rubles and stock availability are given. At the end there is a summary compatibility matrix, a review of typical faults and a separate section on related items: patient sensors for OmniBed.

1. Why an incubator fleet needs a dedicated reserve

An incubator and an infant warmer are continuous-duty equipment: they are not switched off between procedures but run for weeks. This leads to three servicing specifics:

  • •assemblies operating in a constant thermal regime wear out: heating modules, the humidifier, the fan;
  • •mechanical consumables (latches, rings, heating lamps) fail suddenly and cost little;
  • •labor monitoring electronics require a separate reserve, because their failure only becomes visible at the moment of delivery.

The reserve logic is simple: keep one or two assemblies of each class per unit and do not wait for delivery (lead time is confirmed at order placement) while a neonatal place stands idle.

2. Heating: motor assembly, bed and heating lamp

PN M1110788-S — heater motor assembly for 230 V warmer

No official catalog description is provided for this item; the card states the purpose — heater motor assembly for a 230 V warmer, compatible equipment — GE Giraffe.

Approximate price: 275,000 ₽ · Availability: 2 pcs.

This is the most expensive item in the selection. The motor assembly is responsible for heating the working volume, so its replacement is planned in advance: with 2 pcs. in stock, the item should be reserved for a group of machines rather than for each incubator separately.

PN 6600-1041-700 — bed heating module for the Giraffe combined incubator (RoHS)

No official catalog description is provided; the item name states the RoHS version and compatibility with Giraffe OmniBed.

Equipment: Giraffe OmniBed · Approximate price: 9,900 ₽ · Availability: 10 pcs.

The bed heating module is the working surface on which maintaining the newborn's body temperature depends. Availability of 10 pcs. is intended for scheduled replacement in several machines at once.

PN 2045962-001 — heating lamp assembly (230/240V 540)

Official catalog description: Heating element 230/240V 540 (assembly)

Equipment: for GE Lullaby Warmer (ACS) infant warmers · Approximate price: 72,600 ₽ · Availability: 3 pcs.

The heating lamp is the replaceable heating element of the Lullaby warmer: once its resource is exhausted, heating becomes uneven and the time to reach operating mode increases.

3. Humidification: humidifier tube and lower reservoir

PN 6600-0224-850 — Omnibed humidifier heating tube kit

Official catalog description: Omnibed humidifier heating tube kit. Heating block. When replacing spare part 6600-0224-850, spare part 6600-1714-500 must be replaced at the same time.

Equipment: Giraffe OmniBed · Approximate price: 33,000 ₽ · Availability: 3 pcs.

An important practical detail is contained directly in the catalog description: replacement of 6600-0224-850 is performed together with item 6600-1714-500. When planning the tube replacement, order both items — otherwise the assembly will have to be opened a second time.

PN 6600-1493-500 — lower water reservoir for the Giraffe incubator humidifier

No official catalog description is provided. Equipment: Giraffe OmniBed · Approximate price: 8,800 ₽ · Availability: 5 pcs.

The reservoir is a consumable part of the humidification circuit: it is removed for washing and disinfection, so having it in reserve shortens downtime caused by the lack of a clean container.

4. Ventilation and environment control

PN 6600-0828-700 — fan replacement kit

Official catalog description (English): FAN REPLACEMENT KIT

Equipment: Giraffe Incubator · Approximate price: 8,800 ₽ · Availability: 5 pcs.

The fan provides air circulation in the working volume and cooling of the electronics. Its wear shows up as noise, vibration and temperature instability in the chamber.

PN 2075908-001 — ambient sensor kit

No official catalog description is provided. Equipment: Giraffe OmniBed · Approximate price: 17,600 ₽ · Availability: 20 pcs.

The ambient sensor participates in the temperature and humidity control loop of the working volume. Availability of 20 pcs. makes it possible to keep the item in permanent reserve for the entire OmniBed fleet.

5. Power: 12V 65W unit

PN 2075961-001 — 12V 65W power supply

Official catalog description: 12V 65W power supply

Equipment: Giraffe/Panda Warmer · Approximate price: 17,600 ₽ · Availability: 3 pcs.

The item covers two families at once — Giraffe and Panda Warmer. A power supply is a typical candidate for failure after mains voltage fluctuations, so with a fleet of warmers it is kept in reserve.

6. Mechanics and consumables: latch and roller ring

PN 6600-1403-500 — side panel latch

Official catalog description: Side wall latch rod (cast manufacturing)

Equipment: Giraffe OmniBed · Approximate price: 2,200 ₽ · Availability: 10 pcs.

The latch is a mechanical consumable: as it wears, the side wall is not secured, which means the tightness of the working volume and the thermal regime are compromised.

PN 1505-3225-000 — roller seal ring

No official catalog description is provided. Equipment: Engstrom · Approximate price: 6,600 ₽ · Availability: 10 pcs.

The roller ring is an inexpensive item with a high cost of downtime: play and leakage through the mechanism cost more than the seal itself.

7. Labor monitoring electronics: Corometrics 250 boards

PN 2025177-011 — oxygen holder board for Corometrics 250 (with Masimo pulse oximetry board)

No official catalog description is provided. Equipment: Corometrics 250CX · Approximate price: 88,000 ₽ · Availability: 1 pc.

PN 2025177-065 — FECG/UA board for Corometrics 250 (without MECG)

Official catalog description (English): The Corometrics 250 FECG/UA without MECG Board ROHS in Maternal-Infant Care is used in CORO 250 series and other medical equipments as applicable. It is a circuit board which consists of the resistor, capacitor, jumper, connector headers, IC’s, diode and choke. The product is made from the material which possess corrosion resistant, impact resistant, ductility, excellent performance and increased lifespan. The circuit board is a ROHS compliant and is approved for today’s safety standards. The GE product is an innovation and technology, which fits well into versatile customer needs. The product is securely packaged inside a high quality packing box to avoid physical damage during transit and labeled with details about the product, Quality Assurance (QA) seal and shipment details.

Equipment: Corometrics 251CX · Approximate price: 88,000 ₽ · Availability: 1 pc.

According to the official description, the board belongs to the maternal and infant care system and is used in the CORO 250 series: it consists of resistors, capacitors, jumpers, connectors, integrated circuits, diodes and a choke, is made from corrosion- and impact-resistant materials and complies with RoHS requirements. Note the discrepancy on the card: the name indicates the 250 series, while the compatibility section declares Corometrics 251CX — before purchasing, confirm compatibility by serial number.

Both boards are available in stock at 1 pc. each, so these are reserve items for a specific machine, not for a group.

8. Related items: patient sensors for OmniBed

The same class of equipment includes a group of patient sensors already described in the MediAccessori catalog. These are related items rather than heating or humidification replacement assemblies, so they are listed separately:

  • •2045964-001 — reusable monitor sensor for the Care Plus (CP) infant incubator; official catalog description: reusable monitor sensor kit for the Care Plus (CP) infant incubator; approximate price 8,800 ₽, with 10 pcs. in stock.
  • •2074816-001 — disposable temperature sensor; official catalog description: DISPOSABLE PATIENT PROBE ROHS QUANTITY 10; equipment Giraffe OmniBed; approximate price 40,700 ₽, with 3 pcs. in stock.
  • •2075796-001 — reusable patient sensor, RoHS; no official catalog description is provided; equipment Giraffe OmniBed; approximate price 9,900 ₽, with 5 pcs. in stock.

Patient sensors are a consumable part of newborn temperature monitoring: disposable items are purchased in batches according to the department protocol, reusable ones as a reserve for a shift.

9. Compatibility matrix (summary)

PNName (catalog)EquipmentPrice, ₽Availability
M1110788-SHeater motor assembly for 230 V warmerGE Giraffe275,0002 pcs.
2025177-011Oxygen holder board for Corometrics 250 (with Masimo pulse oximetry board)Corometrics 250CX88,0001 pc.
2025177-065FECG/UA board for Corometrics 250 (without MECG)Corometrics 251CX88,0001 pc.
2045962-001Heating lamp assembly (230/240V 540)Lullaby Warmer -ACS72,6003 pcs.
6600-0224-850Omnibed humidifier heating tube kitGiraffe OmniBed33,0003 pcs.
2075961-00112V 65W power supplyGiraffe/Panda Warmer17,6003 pcs.
2075908-001Ambient sensor kitGiraffe OmniBed17,60020 pcs.
6600-1041-700Bed heating module for the Giraffe combined incubator (RoHS)Giraffe OmniBed9,90010 pcs.
6600-1493-500Lower water reservoir for the Giraffe incubator humidifierGiraffe OmniBed8,8005 pcs.
6600-0828-700Fan replacement kitGiraffe Incubator8,8005 pcs.
1505-3225-000Roller seal ringEngstrom6,60010 pcs.
6600-1403-500Side panel latchGiraffe OmniBed2,20010 pcs.

Related items (patient sensors, section 8): 2045964-001 — 8,800 ₽, 10 pcs.; 2074816-001 — 40,700 ₽, 3 pcs.; 2075796-001 — 9,900 ₽, 5 pcs.

The table is built from the MediAccessori catalog cards. Items without an official description are given by the purpose stated on the card. Final compatibility for a specific machine serial number is confirmed by a service engineer.

10. Typical faults and diagnostic sequence

  • •The chamber temperature does not reach mode, heating is uneven — check the heater motor assembly (M1110788-S), the bed heating module (6600-1041-700) and the heating lamp (2045962-001).
  • •Humidity does not rise, condensate appears in the circuit — check the humidifier heating tube (6600-0224-850) and the lower reservoir (6600-1493-500).
  • •Noise and vibration, unstable environment readings — check the fan kit (6600-0828-700) and the ambient sensor (2075908-001).
  • •The side wall is not secured, working volume tightness is compromised — check the side panel latch (6600-1403-500).
  • •The machine does not turn on or shuts down under load — check the 12V 65W power supply (2075961-001).
  • •No cardiotocography or pulse oximetry recording with the monitor running — check the Corometrics 250 boards (2025177-011, 2025177-065).

The diagnostic order is from cheap to expensive: mechanical consumables, sensors and power, then boards and heating assemblies.

11. How to plan the reserve and the purchase

A practical scheme for a department with a fleet of GE incubators and warmers:

  • •permanent reserve — latch 6600-1403-500 (2,200 ₽), roller seal ring 1505-3225-000 (6,600 ₽), fan kit 6600-0828-700 (8,800 ₽);
  • •scheduled replacement during maintenance — bed heating module 6600-1041-700 (9,900 ₽), power supply 2075961-001 (17,600 ₽), ambient sensor kit 2075908-001 (17,600 ₽);
  • •reserve for a group of machines — humidifier heating tube 6600-0224-850 (33,000 ₽, plus 6600-1714-500), heating lamp 2045962-001 (72,600 ₽), Corometrics boards 2025177-011 and 2025177-065 (88,000 ₽ each), motor assembly M1110788-S (275,000 ₽).

Related materials: an overview of breathing circuit consumables is in the article ge-anesthesia-circuit-annual-restock-guide; flow sensors for ventilators are in the article ge-engstrom-ventilator-spare-parts-guide; selecting Philips SpO2 and blood pressure accessories is in the article philips-spo2-nibp-accessories-guide; an overview of GE anesthesia machine electronics is in the article ge-anesthesia-carestation-electronic-valve-parts-guide.

12. Where to buy

MediAccessori supplies spare parts for GE Giraffe, OmniBed, Panda and Lullaby incubators and infant warmers, as well as patient sensors for OmniBed, to Russia and the CIS:

  • •✅ Original GE Healthcare products
  • •✅ Stock availability for the items in this selection — shipment without a long wait
  • •✅ Delivery (lead time confirmed at order placement), documentation for the item
  • •✅ Selection by machine model and section of the service documentation

Contact: Telegram @GEpartsV_bot or email [email protected].

Sources: MediAccessori catalog (PN M1110788-S / 2025177-011 / 2025177-065 / 2045962-001 / 6600-0224-850 / 2075961-001 / 2075908-001 / 6600-1041-700 / 6600-1493-500 / 6600-0828-700 / 1505-3225-000 / 6600-1403-500; related items 2045964-001 / 2074816-001 / 2075796-001); GE Healthcare documentation; service engineers' practice. For items without an official description, only the purpose from the catalog is given.

Frequently asked questions

How do the heater motor assembly M1110788-S and the bed heating module 6600-1041-700 differ?
These are assemblies of different levels. M1110788-S is a heater motor assembly for a 230 V warmer, compatible equipment on the card — GE Giraffe; the approximate price is 275,000 ₽, with 2 pcs. in stock. 6600-1041-700 is a bed heating module for the Giraffe combined infant incubator (RoHS), compatible equipment — Giraffe OmniBed; the price is 9,900 ₽, with 10 pcs. in stock. No official manufacturer's description is provided on the card for either item, so the installation location is clarified against the machine's service documentation.
What is important to consider when replacing the humidifier heating tube 6600-0224-850?
When replacing spare part 6600-0224-850, spare part 6600-1714-500 must be replaced at the same time — this is stated verbatim in the official catalog description. The item is tied to Giraffe OmniBed, the approximate price is 33,000 ₽, with 3 pcs. in stock. The full text of the official description is given in the article: Omnibed humidifier heating tube kit, heating block.
What is the difference between the boards 2025177-011 and 2025177-065 for Corometrics 250?
2025177-011 is an oxygen holder board for Corometrics 250 (with Masimo pulse oximetry board), compatible equipment Corometrics 250CX. 2025177-065 is an FECG/UA board for Corometrics 250 without MECG, compatible equipment Corometrics 251CX. Both items cost 88,000 ₽, with 1 pc. each in stock. No official catalog description is provided for 2025177-011; the description of 2025177-065 is given in the article in full in English without translation.
Is it worth keeping inexpensive items in permanent reserve — the latch 6600-1403-500 and the fan 6600-0828-700?
Yes, these are inexpensive mechanical consumables with a high cost of downtime. The side panel latch 6600-1403-500 — 2,200 ₽, with 10 pcs. in stock; the fan replacement kit 6600-0828-700 — 8,800 ₽, with 5 pcs. in stock. When the latch wears, the side wall is not secured and the temperature regime in the working volume is compromised, while a worn fan produces noise, vibration and instability of environment readings.
How can I order spare parts for GE infant incubators and warmers for Russia?
MediAccessori supplies spare parts for GE infant incubators and warmers from this selection — from the latch 6600-1403-500 (2,200 ₽) to the motor assembly M1110788-S (275,000 ₽); the full list with prices and availability is given in the compatibility matrix of the article. Write to Telegram @GEpartsV_bot, stating the machine model and serial number — an engineer will confirm the selection, compatibility and availability before payment.

Need the part number?

Send us the equipment model or the part number and we will check it against the catalogue. You can also search the parts catalogue directly.