GE respiratory flow sensors — cleaning and calibration
A guide to cleaning and calibrating respiratory flow sensors for GE Datex Ohmeda AS/3 and S/5. Extend service life and keep measurements accurate.
The respiratory flow sensor is a key sensor on the anesthesia machine and on the ventilator, measuring the patient's ventilation parameters: tidal volume, respiratory rate and minute ventilation. Proper care and timely calibration ensure measurement accuracy and extend service life.
Sensor types on the site
The site offers two models:
- GE respiratory flow sensor (universal): compatible with the GE Ventilator series, plug-and-play
- GE Datex Ohmeda respiratory flow sensor: for Datex Ohmeda AS/3 and S/5 systems, with real-time monitoring of respiratory parameters
Both are original GE spare parts with an exact match of electrical connector and mechanical dimensions.
Cleaning procedure
Before cleaning, disconnect the power and the gas supply:
- Carefully remove the sensor from the patient circuit without kinking the connecting cable
- Rinse the channel with warm water (< 40°C), remove secretions and mucus
- Gently treat the membrane area with a pH-neutral medical detergent
- Rinse thoroughly with plenty of water, avoiding detergent residue
- Place on a clean surface to dry naturally; do not use compressed air
Calibration
Regular calibration ensures measurement accuracy:
- •Zero calibration: performed with the sensor open to atmospheric air
- •Calibration against a reference: where calibration equipment is available — according to the manufacturer's recommendations
- •Frequency: at least once a month under active use
Signs of a fault
- •Drifting or unstable tidal volume readings
- •Inability to perform zero calibration
- •Visible damage to the membrane or housing
- •Frequent false ventilation alarms
Where to buy
Medicaparts supplies original GE respiratory flow sensors:
- •✅ Original GE Healthcare products
- •✅ For AS/3, S/5 and other systems
- •✅ Deliveries to Russia and CIS countries
- •✅ Lead time confirmed when the order is placed
Telegram: @GEpartsV_bot
Conclusion
Correct care of the respiratory flow sensor — regular cleaning and calibration — substantially extends its service life and ensures accurate monitoring of the patient's ventilation. When signs of a fault appear, timely replacement with an original GE sensor is recommended.
Sources: GE Healthcare documentation, clinical guidelines