← All articles
2026-07-10•~3 min readECGCAM14electrocardiographyGEmonitorCardiosoft

GE ECG Acquisition: CAM14 Module and T2100 Cables — Compatibility and Application Guide

A complete guide to GE ECG accessories: CAM14 ECG acquisition module (900995-003), T2100/Cardiosoft cable (2104403-003). Compatibility, length, where to buy.

Electrocardiography (ECG) is one of the basic diagnostic procedures in a hospital. ECG signal quality depends not only on the monitor, but also on the quality of the patient cable and the signal acquisition module. In this guide we look at two key components of the GE ECG ecosystem: the CAM14 acquisition module and T2100 patient cables.

CAM14 ECG acquisition module (900995-003)

CAM14 is an ECG signal acquisition module for CARESCAPE monitors and other GE systems. It provides acquisition of up to 14 leads using the standard method.

Technical specifications:

ParameterValue
Part number900995-003
Number of leadsup to 14
Patient cable connectorProprietary (GE T2100)
CompatibilityCARESCAPE B450/B650/B850, MAC series, Cardiosoft
FeaturesDigital signal processing, defibrillation protection

Applications:

  • •Bedside monitoring in the ICU and cardiac intensive care
  • •Stress testing in cardiology
  • •Ambulatory electrocardiography (Holter, event monitoring)
  • •Operating rooms with extended cardiac monitoring

Advantages of CAM14 over previous-generation modules:

  • •Improved protection against motion artifacts
  • •Support for pediatric leads (via additional cables)
  • •Compatibility with GE MUSE software for archiving

T2100/Cardiosoft ECG cables (2104403-003)

The patient cable is the link between the electrodes on the patient's body and the CAM14 acquisition module. Signal clarity depends directly on its quality.

Specifications of cable 2104403-003:

ParameterValue
Part number2104403-003
TypeECG patient cable (main patient cable)
Length1 m (standard)
Connector to monitorProprietary for CAM14
Connector to leadsBanana / snap (replaceable)
CompatibilityT2100, Cardiosoft, CAM14
Lead standardAHA and IEC (switchable)

Differences from disposable cables:

  • •Reinforced insulation for repeated disinfection
  • •Reinforced joints for a long service life
  • •Compatibility with all electrode types: disposable (for single procedures) and reusable (for long-term monitoring)

Compatibility by system

SystemCAM14 (900995-003)T2100 cable (2104403-003)
CARESCAPE B450✅✅
CARESCAPE B650/B850✅✅
Dash 3000/4000/5000⚠️ via adapter⚠️ via adapter
Cardiosoft✅✅
MAC 1200/1600/2000/3500✅✅
MAC 5500✅ (with adapter)⚠️

Maintenance recommendations

Frequency:

  • •Visual inspection of the cable — weekly
  • •Insulation check — monthly
  • •Cable replacement — in case of visible damage or after 500+ cycles

Storage:

  • •In a dry place at a temperature of 10–30°C
  • •Without twisting (store uncoiled or in a large coil)
  • •Away from sources of magnetic fields

Typical mistakes when choosing ECG cables

Mistake 1: buying a cable from a photo, without confirming the part number. CAM14 has several revisions, each with its own cable.

Mistake 2: using a cable from one manufacturer with a module from another. A standard plug may fit physically, but it will not provide correct calibration.

Mistake 3: saving on the patient cable. A cheap cable is the main source of artifacts and noise on the ECG.

Where to buy original GE ECG accessories

MediAccessori supplies:

  • •✅ CAM14 900995-003 (original GE Healthcare)
  • •✅ T2100/Cardiosoft cables 2104403-003
  • •✅ Help in checking compatibility with your equipment
  • •✅ Delivery to Russia and the CIS — lead time confirmed when the order is placed
  • •✅ Full documentation: COO, MSDS, conformity

Telegram for ordering: @GEpartsV_bot

Conclusion

GE ECG accessories are a pairing of "acquisition module + patient cable", where the quality of both components determines the final diagnostic accuracy. Use original CAM14 and T2100 for reliable cardiac monitoring in your clinic.

Sources: GE Healthcare Clinical Accessories Manual, GE MUSE technical bulletins.

Frequently asked questions

Are CAM14 and CAM-14 the same thing?
Yes, CAM14 (also written as CAM-14) is a 14-lead ECG signal acquisition module from GE Healthcare. Part number 900995-003 refers to a specific revision of the module.
Which GE monitors is CAM14 suitable for?
CAM14 is compatible with CARESCAPE B450/B650/B850 monitors, Dash 3000/4000/5000 (via an adapter), as well as Cardiosoft and MAC-1200/1600/2000/3500 systems.
What are the features of the T2100 ECG cable?
Cable 2104403-003 is an ECG patient cable for T2100 and Cardiosoft systems. It has reinforced insulation for repeated use and is compatible with standard AHA and IEC leads.
I bought a CAM14 but have no original cable — can it be substituted?
Not recommended. CAM14 has a proprietary connector and calibration parameters designed for the original T2100 cable. Non-original cables may produce artifacts or not be recognized by the monitor at all.
Are CAM14 and T2100 available in Russia?
MediAccessori supplies CAM14 900995-003 and T2100 cables 2104403-003 directly from GE: in stock, delivery (lead time confirmed when ordering). Telegram: @GEpartsV_bot.

Need the part number?

Send us the equipment model or the part number and we will check it against the catalogue. You can also search the parts catalogue directly.