PEEP 7100 (1504-3016-000) and QUIK-FIL: calibrating the anesthesia machine

Anesthesia machine servicing: why calibrate PEEP/INSP with tool 1504-3016-000, and how to fill sevoflurane safely through the QUIK-FIL adapter 115-026747-00.

Anesthesia machine servicing: the PEEP 7100 calibration tool (1504-3016-000) and the QUIK-FIL adapter for sevoflurane (115-026747-00)

The anesthesia machine is a complex system combining medical gas delivery, anesthetic vaporizers and a breathing block. The condition and accuracy of its components directly affect patient safety. Two important elements of servicing are regular calibration of the breathing block pressure and safe filling of the anesthetic.

In this guide we look at the PEEP/INSP calibration tool for the 7100 breathing block (PN 1504-3016-000) and the QUIK-FIL adapter for sevoflurane (PN 115-026747-00) — their purpose, application, compatibility and purchasing for clinics in Russia and the CIS.

1. Why anesthesia machine servicing matters

Anesthesia machines work in anesthesiology departments and operating theatres every day. The accuracy of gas dosing and of the pressure in the circuit determines:

  • •the correctness of the patient's anesthesia and ventilation;
  • •the stability of PEEP and peak pressure parameters;
  • •the consumption of expensive anesthetics;
  • •the safety of the operating theatre staff.

Routine servicing includes checking and calibrating pressure, leak testing of the circuit, checking the vaporizers and replacing wear parts.

2. The PEEP/INSP calibration tool 7100 (1504-3016-000)

PN: 1504-3016-000

Category: service tool for calibrating PEEP and inspiratory pressure of the 7100 breathing block.

  • •Used during service of the 7100 breathing block of the anesthesia machine (Aestiva platform).
  • •Allows checking and adjusting the accuracy of PEEP pressure and inspiratory pressure (INSP).
  • •Applied by trained service personnel according to GE regulations.
  • •In the Medicaparts catalogue the item is described as "Tool Service PEEP/INSP CAL" — a calibration tool for the 7100 breathing block.
⚠️ Pressure calibration is a technical servicing procedure that requires qualification. If you have no in-house service team, contact an accredited service organisation.

2.1. What the 7100 breathing block is

The 7100 breathing block is the ventilator part of a number of GE anesthesia machines (Aestiva platform). The block provides forced ventilation of the patient's lungs and pressure control in the circuit. The accuracy of its calibration determines the correctness of the pressure readings and of ventilation performance.

2.2. When calibration is needed

  • •During scheduled technical servicing according to the regulations.
  • •After replacing breathing block components.
  • •When pressure deviations from the set values are detected.
  • •After prolonged operation without servicing.

3. The QUIK-FIL adapter for sevoflurane (115-026747-00)

PN: 115-026747-00

Category: adapter (connector) for filling a sevoflurane vaporizer from a bottle with the QUIK-FIL system.

  • •Provides leak-free filling of the vaporizer without spilling the anesthetic.
  • •Intended for sevoflurane — one of the most widely used inhalational anesthetics.
  • •Selected to match the type of vaporizer on the anesthesia machine.
  • •Simplifies and speeds up the filling procedure, reducing contamination of the operating theatre air.
The QUIK-FIL system is a common interface for sevoflurane bottles. Adapter 115-026747-00 allows the bottle to be connected to the vaporizer safely. Confirm the exact match to your vaporizer with an engineer.

3.1. Why the adapter is needed

When filling a vaporizer, an incorrect bottle connection can lead to:

  • •spilling the anesthetic and contaminating the operating theatre;
  • •contaminants and moisture entering the vaporizer;
  • •underfilling or overfilling the vaporizer;
  • •unnecessary consumption of an expensive drug.

The QUIK-FIL adapter eliminates these risks: the connection is leak-free and filling is controlled.

3.2. Safety rules when filling sevoflurane

  1. Fill the vaporizer only when the machine is switched off and has cooled down.
  2. Check that the adapter is serviceable and the bottle is intact.
  3. Do not overfill the vaporizer — watch the level.
  4. Do not use damaged bottles or adapters.
  5. If anesthetic gets on the skin or into the eyes, follow the manufacturer's instructions.

4. Compatibility table

PNItemEquipment typeNote
1504-3016-000PEEP/INSP calibration toolanesthesia machine (7100 block, Aestiva)service tool; requires qualification
115-026747-00QUIK-FIL adapter for sevofluranesevoflurane vaporizer of the anesthesia machineconfirm the vaporizer type
Exact compatibility depends on the machine and vaporizer model. Before ordering, send the device model to an engineer.

5. Common mistakes

  • •Doing the calibration yourself without preparation. Loss of pressure accuracy and patient safety.
  • •Filling the anesthetic with the machine switched on. Risk of overheating and dosing errors.
  • •Using an unsuitable adapter. Leaks and contamination of the vaporizer.
  • •Ignoring the servicing schedule. Gradually increasing parameter deviations.
  • •Using damaged bottles and adapters. Risk for staff and patient.

6. Delivery and purchasing

Medicaparts supplies tools and accessories for anesthesia machines to Russia and the CIS:

  • •Lead time is confirmed when the order is confirmed.
  • •Rare items: lead time is confirmed when the order is confirmed.
  • •Help with selection by model and PN.
  • •Provision of accompanying documentation.

7. How to order

  1. Write on Telegram @GEpartsV_bot or by email to [email protected].
  2. State the anesthesia machine model, the type of breathing block/vaporizer and the required PN.
  3. An engineer will confirm compatibility and issue a quotation.
  4. Contract/invoice, prepayment, delivery.

8. Contacts

Sources: Medicaparts catalogue (products_accessories, PN 1504-3016-000 / 115-026747-00); GE Healthcare documentation; service engineers' experience.

Frequently asked questions

What is the PEEP/INSP calibration tool 7100 (1504-3016-000) intended for?
Tool 1504-3016-000 is used during servicing of the 7100 breathing block of anesthesia machines (Aestiva platform) to calibrate PEEP and inspiratory pressure (INSP). Service engineers use it to check and adjust the pressure accuracy in the breathing circuit.
Which anesthesia machines use the 7100 breathing block and need this tool?
The 7100 breathing block is used in GE anesthesia machines on the Aestiva platform. PEEP/INSP calibration is performed as part of the service schedule by trained personnel or a service organisation. Before ordering, state the machine model and the type of breathing block.
What function does the QUIK-FIL adapter for sevoflurane (115-026747-00) perform?
The QUIK-FIL adapter is intended for safe filling of a sevoflurane vaporizer from a bottle with the QUIK-FIL system. It prevents spilling of the anesthetic and contamination entering the vaporizer. Version 115-026747-00 is selected to match the type of vaporizer on the anesthesia machine.
What are the safety rules when filling sevoflurane?
Fill the vaporizer only with the machine switched off and cooled down, use a serviceable QUIK-FIL adapter, do not overfill the vaporizer, and avoid spilling the anesthetic. Do not use damaged bottles or adapters. If anesthetic gets on the skin, follow the manufacturer's instructions.
Where can I buy 1504-3016-000 and 115-026747-00 with delivery to Russia?
Medicaparts supplies tools and adapters for anesthesia machines to Russia and the CIS; lead time is confirmed when the order is confirmed (including for rare items). Contact us on Telegram @GEpartsV_bot, stating the anesthesia machine model and the vaporizer type.

Need the part number?

Send us the equipment model or the part number and we will check it against the catalogue. You can also search the parts catalogue directly.