The air filter is a simple but critical part of medical equipment. It protects internal components from dust and contamination and, depending on the design, ensures the cleanliness of the air supplied to the system. Timely filter replacement is part of regular technical maintenance.

In this guide we examine the air filter 2107356-001 from the MediAccessori catalog and explain how to select it correctly, replace it and buy the original.

1. Why an air filter is needed

Medical equipment (incubators, respiratory equipment, compressor and ventilation systems) draws air from the room. Without a filter:

  • •dust and fibers get inside the housing and settle on the electronics;
  • •moisture contaminates sensors and fans;
  • •heat dissipation and cooling of the systems are disrupted;
  • •the risk of overheating and component failure increases.

The filter retains contaminants and extends the service life of the equipment, reducing repair costs.

2. Signs that the filter is due for replacement

  • •Visible contamination of the filter surface (dust, darkening).
  • •Deterioration of air flow / heating of the equipment housing.
  • •Frequent false temperature or pressure alarms.
  • •Increased fan noise (resistance to flow).

If these signs appear, check the filter and replace it.

3. Replacement interval

  • •Factory schedule: usually 6–12 months or according to the model's instructions.
  • •In dusty rooms — more often.
  • •Replace at every sign of contamination.
  • •When purchasing, it is useful to keep a filter in reserve so as to avoid equipment downtime.
The exact schedule is given in the service manual of the specific device.

4. How to select filter 2107356-001

Step 1. Identify the equipment model The brand, model and generation of the device in which the filter is installed.

Step 2. Check the mounting seat The size, the fastening, the installation direction of the filter.

Step 3. Verify the PN Compare it with 2107356-001. If in doubt, send a photo of the filter and the model to the engineer.

5. How to replace the air filter

  1. Disconnect the equipment from the mains (according to the instructions).
  2. Open the filter compartment/cover.
  3. Remove the old filter.
  4. Install the new 2107356-001 while observing the flow orientation.
  5. Close the compartment, switch the equipment on and check operation.

6. Compatibility table

PNItemEquipment typeNote
2107356-001air filterGE medical equipment (maternal and infant care category)verify the model and the mounting seat
Exact compatibility depends on the model. Before ordering, send the device model to the engineer.

7. Common mistakes

  • •Buying without the equipment model. Filters are not universal in terms of the mounting seat.
  • •Replacing with an analogue "by eye". A size mismatch breaks the seal.
  • •Ignoring the maintenance schedule. A clogged filter leads to overheating and failures.
  • •Installing without checking the orientation. The wrong flow direction impairs filtration.

8. Delivery and purchasing

MediAccessori supplies original GE air filters to Russia and the CIS:

  • •The delivery time is confirmed when the order is confirmed.
  • •Rare items: the time is confirmed when the order is confirmed.
  • •Assistance in selecting by model and PN.
  • •Provision of accompanying documentation.

9. How to order

  1. Write to Telegram @GEpartsV_bot or to email [email protected].
  2. State the equipment model and the PN 2107356-001.
  3. The engineer will confirm compatibility and issue a quotation.
  4. Contract/invoice, prepayment, delivery.

10. Contacts

Sources: MediAccessori catalog (products_current.json, PN 2107356-001); GE Healthcare service schedules; the experience of service engineers.

Frequently asked questions

What role does the air filter (2107356-001) perform in medical equipment?
The filter protects internal components (fan, compressor, sensors, electronics) from dust, moisture and contamination, and in some systems ensures the cleanliness of the supplied air. A contaminated filter disrupts cooling and the operation of the equipment.
How often should the air filter be replaced?
The interval depends on the type of equipment and the dustiness of the room. The factory schedule usually provides for replacement once every 6–12 months or when visible contamination appears. Check the service manual of the model.
How do I know whether 2107356-001 is compatible with my equipment?
Compatibility is determined by the model and generation of the device, as well as by the type of filter mounting seat. Have the equipment model and the installed filter checked with the engineer; send a photo if in doubt.
What are the risks of not replacing/cleaning the filter in time?
A clogged filter obstructs the air flow, leads to overheating of internal components, unstable operation and false alarms, and in some systems to contamination of the gas line. This increases the risk of equipment failure.
Where can I buy the original 2107356-001 with delivery to Russia?
MediAccessori supplies original air filters 2107356-001 to Russia and the CIS; the delivery time is confirmed when the order is confirmed. Contact us via Telegram @GEpartsV_bot, stating the equipment model.

Need the part number?

Send us the equipment model or the part number and we will check it against the catalogue. You can also search the parts catalogue directly.