GE anesthesia machine spare parts
Parts and consumables for GE anesthesia machines (Datex Ohmeda, Aestiva, Avance, Aisys and CARESCAPE lines): D-Fend and D-Fend Pro water traps, APL valves, breathing circuit components, bellows, gas sampling lines, flow sensors and oxygen cells.
53 items in this category · select by part number (PN) or equipment model.
AnesthesiaGE Anesthesia Machine Bellows
GE Anesthesia Machine Bellows (PN 1500-3378-000) is an anesthesia machine part for GE Healthcare equipment. The part number identifies the item; compatibility with a specific machine is confirmed by PN before ordering.
1500-3378-000
AnesthesiaAir/Oxygen Mixer Board
Air/Oxygen Mixer Board (PN 1011-8000-000-S) is an anesthesia machine part for GE Healthcare equipment. The part number identifies the item; compatibility with a specific machine is confirmed by PN before ordering.
1011-8000-000-S
AnesthesiaAPL Diaphragm
For use with: Aestiva
DIAPHRAGM APL BCG
1406-3331-000
AnesthesiaC600 Oxygen Sensor
For use with: GE 600
C600 Oxygen Sensor (PN 2071018-001-S) is an anesthesia machine part for GE Healthcare equipment. The part number identifies the item; compatibility with a specific machine is confirmed by PN before ordering.
2071018-001-S
AnesthesiaSoda Lime Canister
For use with: GE Datex Ohmeda
Soda Lime Canister (PN 1407-7004-000) is an anesthesia machine part for GE Healthcare equipment, used with Datex Ohmeda. The part number identifies the item, and the compatible equipment models confirmed for it are listed on this page.
1407-7004-000
GE M10 Anesthesia Machine Oxygen Sensor
For use with: GE Datex Ohmeda: Aespire, Carestation, Avance, AS/3, S/5
GE M10 Anesthesia Machine Oxygen Sensor (PN M10) is an anesthesia machine part for GE Healthcare equipment, used with AS/3, Aespire, Avance, Carestation, Datex Ohmeda. The part number identifies the item, and the compatible equipment models confirmed for it are listed on this page.
M10
AnesthesiaAPL Valve
For use with: Aelite NXT
APL Valve (PN 2100552-001-S) is an anesthesia machine part for GE Healthcare equipment, used with Aelite NXT. The part number identifies the item, and the compatible equipment models confirmed for it are listed on this page.
2100552-001-S
AnesthesiaVALVE FLPR 1.062D .875L W/TPR STEM SIL BCG
VALVE FLPR 1.062D .875L W/TPR STEM SIL BCG (PN 0211-1454-100) is an anesthesia machine part for GE Healthcare equipment. The part number identifies the item; compatibility with a specific machine is confirmed by PN before ordering.
0211-1454-100
D-Fend Pro Water Trap (Black)
For use with: GE D-Fend: D-Fend Pro
D-Fend Pro Water Trap (Black) (PN 876446-HEL) is an anesthesia machine part for GE Healthcare equipment, used with D-Fend, D-Fend Pro. The part number identifies the item, and the compatible equipment models confirmed for it are listed on this page.
876446-HEL
AnesthesiaNitrous Oxide Needle Valve
For use with: GE Aespire
Nitrous Oxide Needle Valve (PN 1006-8345-000) is an anesthesia machine part for GE Healthcare equipment, used with Aespire. The part number identifies the item, and the compatible equipment models confirmed for it are listed on this page.
1006-8345-000
AnesthesiaAPL Valve
For use with: Aestiva
APL Valve (PN 1406-8202-000-S) is an anesthesia machine part for GE Healthcare equipment, used with Aestiva. The part number identifies the item, and the compatible equipment models confirmed for it are listed on this page.
1406-8202-000-S
AnesthesiaOxygen Cell Cable
For use with: Anesthesia Other
CABLE O2 SENSOR
1006-3141-000
AnesthesiaBellows U-Cup Seal
For use with: Aestiva
SEAL U-CUP ABA
1500-3359-000
AnesthesiaCondenser Assembly
For use with: GE Aespire
Tube Assembly Breathing Circuit Gas (BCG) Mechanical
1407-3133-000-S
AnesthesiaSoda Lime Canister Lid
For use with: 1407-7004-000
COVER ASSY CO2 CANISTER WITH BRACKET AND O-RING
2101113-001-S
AnesthesiaC600 Power Board
For use with: Carestation 600 Series
ACIN 100-240V, DCOUT: 12.6V, ECM140US12-A-XA1049
2076733-001-S
AnesthesiaCheck Valve Assembly
For use with: Carestation 600 Series
CHECK VALVE ASSY
2071067-001-S
AnesthesiaElbow Connector
For use with: 9 Series -ACS
Elbow Connector 1/8"inch 3.2mm Inner Diameter (ID)
M1171751-S
AnesthesiaViewing Port Plug
For use with: Aestiva
OEM, PLUG SIGHTGLASS
0229-2080-100
AnesthesiaC30 Oxygen Sensor
For use with: Carestation 30 -ACS
Assembly Oxygen Sensor
M1223210-S
AnesthesiaSeal Ring
For use with: Aespire
PART, O-RING OD30 ID22 4W BCG SILICONE 40 DURO, Injection molded
1407-3104-000
AnesthesiaO-Ring
PART, O-RING .562ID .750OD .093W SILICONE 45-55DURO
0210-0463-300
AnesthesiaSingle-Use Spirometry Tube, 3 m
Spirometry Tubes, Single Patient Disposables, 3M, Yellow (QTY 5)
884101
AnesthesiaO-Ring
For use with: GE Datex Ohmeda
PART, O-RING 34.59ID 39.83 BCG OD 2.62 W EPR 60 DURO, Injection molded
1503-3208-000
Anesthesia7100 PEEP Calibration Tool
For use with: Aestiva
TOOL SERV PEEP/INSP CAL ABS 7100 VENT
1504-3016-000
AnesthesiaSevoflurane QUIK-FIL Adapter Assembly
Sevoflurane QUIK-FIL Adapter Assembly (PN 115-026747-00) is an anesthesia machine part for Mindray equipment. The part number identifies the item; compatibility with a specific machine is confirmed by PN before ordering.
115-026747-00
AnesthesiaSystem Disk
For use with: 9100C,NXT
System Disk (PN 2107870-120) is an anesthesia machine part for GE Healthcare equipment. The part number identifies the item; compatibility with a specific machine is confirmed by PN before ordering.
2107870-120
AnesthesiaAPL Valve
For use with: AESPIRE 7100
APL Valve (PN 2106569-001-s) is an anesthesia machine part for GE Healthcare equipment, used with AESPIRE 7100. The part number identifies the item, and the compatible equipment models confirmed for it are listed on this page.
2106569-001-s
AnesthesiaOxygen Cell Cable
For use with: GE M10
Oxygen Cell Cable (PN 1009-5570-000) is an anesthesia machine part for GE Healthcare equipment. The part number identifies the item; compatibility with a specific machine is confirmed by PN before ordering.
1009-5570-000
Anesthesia9100C NXT Maintenance Kit, Year 1, 2099998-001-S
For use with: 9100C NXT
9100C NXT MAINTENANCE KIT YEAR ONE
2099998-001-S
AnesthesiaPush-Button Encoder
ENCODER ROTARY 16 POSN W/PUSH BUTTON SWITCH
1503-3012-000
D-Fend Pro Water Trap (Clear)
For use with: GE D-Fend: D-Fend Pro
D-Fend Pro Water Trap (Clear) (PN M1182629) is an anesthesia machine part for GE Healthcare equipment, used with D-Fend, D-Fend Pro. The part number identifies the item, and the compatible equipment models confirmed for it are listed on this page.
M1182629
AnesthesiaA180 VENTILATOR ENGINE SERVICE ASSY
For use with: Carestation 600 Series
A180 VENTILATOR ENGINE SERVICE ASSY
2071117-001-S
Anesthesia9100C Display Control Board
For use with: 9100C
ASSY-WXC PWA ASSEMBLY 9100C DISPLAY MONITOR BOARD SPARE PART
M1187892-S2
AnesthesiaBIS Module
BIS Module (PN 6800-30-50851) is an anesthesia machine part for Mindray equipment. The part number identifies the item; compatibility with a specific machine is confirmed by PN before ordering.
6800-30-50851
AnesthesiaDisplay Control Board
For use with: 9100C NXT
Display Control Board (PN M9100000-S) is an anesthesia machine part for GE Healthcare equipment. The part number identifies the item; compatibility with a specific machine is confirmed by PN before ordering.
M9100000-S
AnesthesiaFan Communication Tool
For use with: Carestation 600 Series
OEM PART, KIT FAN COM EXPRESS, Electro-Mechanical
M1220157
AnesthesiaAssembly Vent Engine
For use with: Carestation 30 -ACS
Assembly Vent Engine
M1228087-S
AnesthesiaAPL Valve
For use with: Carestation 600 Series
APL Valve (PN 2090000-001-S) is an anesthesia machine part for GE Healthcare equipment, used with Carestation 600 Series. The part number identifies the item, and the compatible equipment models confirmed for it are listed on this page.
2090000-001-S
AnesthesiaSoda Lime Canister Foam Pad
For use with: 1407-7004-000
Pack of 40
2105489-001
AnesthesiaSeal Ring
For use with: Anesthesia Other
ASSY-MSN, KIT SPARE O-RING VLV PORT STEETON NO 46147
1102-3016-000
AnesthesiaAPL Breathing Circuit Baffle Assembly
For use with: Carestation 600 Series
ASSY DIAPHRAGM APL BCG
2079638-001-S
AnesthesiaFlow Sensor
Autoclavable flow sensor for Compact Breathing System (CBS) devices, such as Carestation™ 600 Series and Carestation 750
2069358-001-S
AnesthesiaSevoflurane Filling Adapter
EASY-FIL BOTTLE ADAPTER, VAPORIZER, SEVOFLURANE
2106572-003
AnesthesiaExhaust line with Colder fitting, 18cm/7in
Exhaust Line with Colder fitting for gas return or scavenging, 18 cm/7 in., connectors: Female Luer-Lok and straight Colder Male Fitting, disposable
8004463
AnesthesiaExhaust line with Colder fitting, 1.0m/41in
Exhaust Line with Colder Fitting for gas return or scavenging, 1m/41 in., connectors: Female Luer-Lok and straight Colder Male Fitting, disposable
8004462
AnesthesiaFlow Sensor
For use with: 9 Series -ACS
A Differential Pressure Sensor Assembly - Phantom is a special type of pressure sensor that measures the change in pressure across two ports on a device. The part Assembly-WXC is a necessary part of the GE 9100C ventilator. The tube and cables are made up of high quality materials and the assembly is more stable under stringent conditions.
M1174442-S1
AnesthesiaAbsorber Seal
For use with: Aestiva
ASSY-MSN, AESTIVA TNA MISC SEALS KIT, Manufacturing assembly - Make
1406-3414-000-S
AnesthesiaAutoclavable Flow Sensor
For use with: GE Datex Ohmeda
Flow sensor – autoclavable: Newest flow sensor designed to work in the presence of moisture with pressure sense lines kink prevention. Single piece flow sensor body design with titanium flapper. Will last for a minimum of 1 year. Can be used in MRI environments.
2087640-001-S
GE Datex Ohmeda Respiratory Flow Sensor
For use with: GE Datex Ohmeda: AS/3, S/5, Aespire, Carestation
GE Datex Ohmeda Respiratory Flow Sensor (PN 2089610-001) is an anesthesia machine part for GE Healthcare equipment, used with AS/3, Aespire, Carestation, Datex Ohmeda. The part number identifies the item, and the compatible equipment models confirmed for it are listed on this page.
2089610-001
AnesthesiaSoda Lime Canister
The Reusable Canister Assembly is one of the parts of the breathing system. It is the container, which is used to remove carbon dioxide from the patient’s exhaled breath. It is reusable so that the canister should be weighted to monitor the lifespan on a regular basis. It should be replaced when the weight is reached as per design. It can be used with the EZChange option. Ejector pins to be flush to 0.3 recessed and gate heights ± 0.3 mm also the maximum flash permissible is 0.05 wide x 0.05 high. All the ribs should be 1.5 ± 0.5° DFT wide unless otherwise specified.
2071165-001-S
AnesthesiaShelf
For use with: Aespire
The Diaphragm & Seat Sub-Assembly is a component of breathing circuit gas system used to regulate the pressure in the breathing circuit. The pressure relief valve assembly provides accurate pressuring while ventilating a patient with the use of diaphragm. The amount of pressure buildup in the bellows should be limited and also gases are to be released for scavenging. For adjusting these pressure limits, a diaphragm and seat subassembly are used as a part of pressure relief valve assembly. These are being used in MS CARESCAPE™ Monitor B650, ARC iCentral, MS Dash™ 4000, ARC Aestiva 7100, MS PRN50 Writer, ARC Airway Gas Module, ARC iVent 201, ARC Testing Service, MIC Giraffe™ Warmer, ARC Aestiva 3000, MS CIC Pro, ARC Anesthesia Monitor, MIC Panda™ iRES Warmer, ARC Aespire 7100, MS Solar 8000, ARC Airway Gas Module, ARC iVent 201, ARC Testing Services, MS CO₂ MODULE, ARC Monitor CardioCap 5, MS CIC Pro v5, ARC Aestiva MRI, ARC Engstrom Carestation, ARC Aestiva 7100, ARC Aisys, ARC Monitor, ARC S/5 Monitor FM, ARC Airway Gas Module, ARC S/5 Monitor Anesthesia, ARC ADU, ARC Monitor CardioCap 5, ARC Airway Gas Module, ARC Light Monitor, ARC ADU, ARC MRI Monitor, ARC Aestiva 7100, ARC Aespire 7900, ARC Tec 6 Plus and ARC Aespire View.
1500-3377-000
AnesthesiaVALVE FLOW CONTROL 120 LPM 12V MPOS
For use with: Aespire
The Flow Control Valve comes as a part of the vent engine manifold of an Anesthesia Delivery System. It is used to control the gas flow through the Medium Pressure Oxygen Service (MPOS) manifold, which is provided as a part of the vent engine in Breathing Circuit Gas (BCG) of the ventilator. The assembly comes into contact with oxygen-enriched gas in the range of 50 to 3000 kPa. The components are corrosive resistant and hence it is highly efficient to use in medical environments.
1503-3854-000-S